• admin@einstinc.com
  • (65) 6276 6928
logo
  • Home
  • About Us
    • Latest News
    • Upcoming Events
    • Past Year Calendar Photos
    • Career
  • Products
  • Engineering
    • Prototyping
    • Customization
  • Services
    • Preventive Maintenance
    • Repairs
    • Relocation/Recommission
    • Training
    • Calibration
  • Technology
    • Application
    • Publications
    • Microscopy Basics
  • Supplier
  • Contact Us
Microscopy
  • Nikon Stereo Microscopes
  • Nikon Upright Microscopes
  • Nikon Inverted Microscopes
  • TOMOCUBE – Holographic Microscope
Digital / High Content / Portable Microscope
  • Nikon Digital Imaging Microscope
  • PRECIPOINT – Digital Microscopes & Scanner
  • ioLight – Portable Microscope
Advance Microscopy
  • ANDOR – High Speed Confocal Microscope System
  • NIKON -TIRF, Confocal Microscope, Multi-Photon System
  • PICOQUANT – MicroTime, LifeTime System
  • PHOTON ETC – IMA Hyperspectral Microscope
  • CYTOVIVA – Hyperspectral Imaging System
  • IVIM Technology – IntraVital Microscope
Scientific Camera
  • ANDOR -EMCCD, sCMOS, CCD Cameras
  • NIKON – Microscope Camera Digital Slight Series & Controller
  • First Light EMCCD, UV, SWIR Camera
  • ARTRAY- USB camera
  • SENOP – Hyperspectral Imaging
  • NIREOS – HERA Hyperspectral Camera
  • PHOTON ETC- Deep Cooled IR Camera
Spectroscopy
  • TECHNOSPEX – uRaman, uSight MicroSpectroscopy
  • AVANTES – Spectrometers
  • PICOQUANT – Fluorescence LifeTime Spectrometer
  • PICOQUANT – Photon Counting Instruments and Detectors
  • ANDOR – Spectrographs and Detectors
  • AGILTRON – Raman Spectrometers
  • PHOTON ETC – In Vivo NIR-II Spectral Probe
  • CLOUDMINDS – Smart Handheld Raman
  • QNW – Peltier-Controlled Cuvette Holders and Custom Instrumentation
  • PHOTON ETC – Infrared Microplate Reader
Laser & Light Sources
  • PICOQUANT – Picosecond Pulsed Diode Laser, Nanosecond Pulsed & Modulated Laser Systems
  • ENERGETIQ – Laser-Driven Light Sources
  • Avantes-Light Source, Calibration Light Source
  • OMICRON LASER Multiwavelength Laser Combiner
  • Photon etc – Supercontinuum Tunable Filter
  • YSL – Femto Second Fiber Laser, Pico Second Fiber Laser and Supercontinuum
  • CNI – Lasers, Fiber Coupled LEDs & Laser Marking System
  • IPS Lasers
  • Teem Photonics
Metrology
  • Bristol Insturments- Wavelength meter, Laser Spectrum Analyzer
Others
  • LINKAM – Temperature Controlled Microscope Stages
  • HOLOEYE – Spatial Light Modulars
  • ATI – 6 Axis Force/ Torque Sensors
  • IBSEN – Phase Masks & Interrogation Monitors
  • Lasershield Eyewear
  • CHROMA – Filters, Mirrors, Lens, Filter Cubes
  • NARISHIGE – Micro Manipulator & Microinjectors
  • BIOPTECHS – Objective Heater, Culture System
  • NANOSCRIBE – 3D Laser Lithography System
  • Cloudmind – Thermal Monitoring Device
  • ANDOR – Optical Cryostats
  • NIREOS – GEMINI INTERFEROMETER
  • TERASENSE – Terahertz imaging cameras, Generators and Ultrafast Terahertz Detectors
  • TeTechS – Terahertz Technology Solutions
Microscopy Accessories
  • Prior Scientific – Motorized Microscope Stages
  • OKOLAB – Microscope Incubators
  • Nikon Microscope Accessories
  • Other Add On Microscope Accessories
Bio-Medical
  • ATCOR Medical – Sphygmocor Technology
  • SunTech Medical – ABPM
Enquiry Form
Enquiry Form

All Products >>Microscopy>>Nikon Upright Microscopes>>Upright Microscope Eclipse Si
  • All Products
  • Microscopy
  • Digital / High Content / Portable Microscope
  • Advanced Microscopy
  • Scientific Camera
  • Spectroscopy
  • Laser & Light Sources
  • Microscopy Accessories
  • Others
  • Bio-Medical
  • Metrology

Upright Microscope Eclipse Si

Focus in comfort. Comfort in focus.

Nikon has designed the ECLIPSE Si to meet the rigorous demands of professionals who spend hours using the microscope. The ECLIPSE Si is ergonomically designed to enhance operational efficiency. This powerful instrument helps you to stay focused for longer by reducing the strain on your body. The ECLIPSE Si is the new standard in microscopes, expanding the possibilities of exploring the micro world.

 

 

  • Key Features
  • Specifications

Pursuing efficient workflow

The ECLIPSE Si has been developed with the primary goal of reducing fatigue during microscope usage. The ECLIPSE Si eliminates unnecessary adjustments and enables efficient and comfortable operation. The ergonomic design also enables natural posture, even when carrying out repetitive tasks.


 

Maintaining comfortable brightness when switching magnifications

Objectives with different magnifications transmit light to varying degrees. Therefore, light intensity must be adjusted every time the user changes the objective. In addition, when switching from high to low magnification objectives, the sudden increase in brightness often causes eye strain. The ECLIPSE Si features the intelligent Light Intensity Management (LIM) which automatically remembers and sets the light intensity level for each objective. The LIM feature reduces up to 40% of the time spent on adjusting light intensities*. With the ECLIPSE Si, users can increase comfort and save time even when the routine requires frequent magnification changes.

* Compared to the time required for adjusting the light intensity when switching among three different objective lenses. Test was carried out by Nikon, using a previous LED-based microscope model.

Push the brightness control knob briefly to activate the LIM feature.

 

LIM feature OFF

Since brightness varies depending on the objective, switching magnifications can induce eye strain.

With high-powered objective With low-powered objective

 

LIM feature ON

The optimal light intensity level is automatically recalled and applied to each objective, therefore eliminating unexpected changes in light intensity when changing magnifications and streamlining workflow.

With high-powered objective With low-powered objective

 

Low stage for effortless slide replacement

The height of ECLIPSE Si stage is 135 mm, which is about 50 mm lower than our conventional microscopes. The lower stage design reduces the range of motion required to exchange specimen slides, and in turn this can reduce arm and shoulder fatigue. Since the position of the stage movement knob is also lower, different areas on the specimen slide can be easily explored while resting your hands on the table. The lever for opening and closing the specimen holder has also been designed to be ergonomic with an easy-to-operate size and shape. Furthermore, the ECLIPSE Si features a 30% smaller stage compared to our conventional microscopes in order to optimise slide replacement.

Conventional microscope ECLIPSE Si
Easy-to-operate specimen holder

 

Enables natural posture to be maintained throughout the entire microscope workflow

The inclination angle of the eyepiece tube is 45 degrees, which enables observation through the eyepieces while maintaining a natural posture. The low stage design also allows you to seamlessly switch from looking through the eyepieces to checking the slide placement on the stage without having to adjust your posture. An optional eye-level riser is also available to further tailor the height of the eyepieces.

Eye-level riser Check on the stage while maintaining the observation posture

 

Worry free focusing thanks to vertical stop

The ECLIPSE Si is equipped with a stopper that can be used to set the upper limit of the stage height. The stage stops at the set height even when the focus knob is turned, thereby eliminating the risk of over-focusing and breaking the slides or damaging the objectives. Specimen exchange and focusing can be performed with confidence, without worrying about the stage height.

Easy operation just by turning the screw at the height you want to set The stage does not rise above the set height.

 

Pursuing stress-free ease of use

We wanted to design a microscope that would eliminate fatigue incurred by frequent specimen exchanges and provide a more comfortable user experience. The ECLIPSE Si combines innovative features and intelligent design to minimize unnecessary body movements, saving time and reducing strain on the user even when examining a large number of slides.

 

Adjusting focus and moving the stage with one hand

The coarse and fine focus knobs are located on both sides of the microscope, making it possible to focus with either hand. In addition, the stage handle is positioned close to the focus knob, allowing users to easily adjust both the stage position and focus with the same hand. With the stage movement and focus controlled by the same hand, the other hand can be dedicated to rotating the nosepiece or replacing the slides. These features provide an efficient workflow even when examining a large number of specimen slides.

Coarse focus knob Fine focus knob
Coarse/fine focus and stage movement can be operated with one hand

 

Status display

The illumination brightness is shown in a bar graph on the LCD. You can check the magnification at a glance while maintaining your observation posture.

❶ECO mode: ON ❷LIM function: ON ❸Objective name ❹Magnification ❺Brightness state


 

Knob rotation direction display

The direction of rotation of the focus and brightness control knobs can be intuitively grasped.


 

No hesitation in choosing a knob to operate

The icon of the stage movement knob to be operated is illustrated on the travel scale of the specimen in the forward-backward and right-left directions.


 

Changing magnifications comfortably

The reversed-type nosepiece provides easy access and visibility to the objective in use. The position of the nosepiece is low to reduce strain on the arm when frequent magnification changes are required. The nosepiece features an easy grip for smooth rotation, and accommodates up to five objectives to provide a wide range of magnifications.

Easy-to-rotate quintuple nosepiece

 

Blocks blue component in LED light

Since LED light contains a large amount of blue or short wavelength light, there is concern that prolonged observation may put a strain on the eyes. The ECLIPSE Si offers an optional blue light blocking filter that can be placed on the field lens to remove the blue component of the LED light.


 

Automatically turning off illumination after a certain period of time

The ECLIPSE Si is equipped with an ECO mode which automatically turns off the illumination after a certain period of inactivity. The length of the inactivity period is adjustable. With ECO mode, the ECLIPSE Si helps you save power without any effort.

Press and hold the brightness control knob to turn on the ECO mode.

 

Easily share images on-site and remotely

Capture specimen images for documentation or for real-time sharing with others by configuring the ECLIPSE Si (trinocular version) with a digital camera.

When the ECLIPSE Si is configured with the Digital Sight 1000 microscope camera (optional), images of specimens can be easily displayed on the monitor for simultaneous observation by multiple people, and recorded without the use of a PC. Furthermore, by connecting the camera to a tablet PC*, images can be shared in real time with remote or off-site PCs and smart devices via a network. The DS-Fi3* high-definition microscope camera, which faithfully captures the true colors of specimens, is also available.

* NIS-Elements L imaging software is required.

Simultaneous observation and display of specimens on a monitor Share images in real-time with PCs in another room or building

 

Superior Optics for High Quality Images

Nikon’s advanced optical technologies, culminating from a long tradition as a microscope manufacturer, play a vital role in the ECLIPSE Si. The ability to fulfill the need for accurate observation of specimens is a source of pride for us.

 

Excellent image flatness and chromatic aberration correction

The ECLIPSE Si employs CFI E Plan series objectives, which feature flat, sharp images up to the periphery of the field of view. These objectives are part of the CFI60 infinity-corrected optical system, which achieves both high resolution and long working distances. A wide variety of Nikon CFI60 objectives are available.

CFI E Plan series objectives

 

Observation with FOV of 22mm

The ECLIPSE Si can enhance the efficiency of clinical observations when equipped with FOV22 tubes* and lenses that enable a large 22mm field of view.

*C-TB, C-TF, C-TT and C-TE2 tubes


 

Long-life LED with constant color temperature

The high-intensity, white LED light source, features a long life of up to 60,000 hours. Since the color temperature remains constant even when the brightness is changed, the color of the image does not change when changing magnifications.


 

Uniform brightness up to the periphery of the field of view

The illumination system features an integrated fly-eye lens which provides uniform brightness over the entire field of view.

Fly-eye lens

 

Blocking light from outside the field of view

The ECLIPSE Si is equipped with a field diaphragm that can be used to limit the illumination range for optimal observation and image acquisition. Adjusting the field diaphragm suppresses the occurrence of flare and ghosting, enabling high contrast image observation. During fluorescence observation, the range of photobleaching of specimens can also be limited.

Turn the field diaphragm dial until the illumination range is circumscribed to the field of view.

 

Compatible with a Wide Variety of Observation Methods

Using optional accessories, the ECLIPSE Si allows for a wide variety of observation methods in addition to brightfield.

Specimen Gallery

 

Brightfield observation

High-quality images can be acquired with bright, uniform illumination over the entire field of view, using objectives with superior image flatness and excellent chromatic aberration correction.


 

Phase contrast observation

Combining of a phase condenser and phase contrast objectives enables observation of colorless and transparent specimens with high contrast, without staining or labeling the specimens with dyes. A standard Abbe condenser, with a PH slider inserted, also allows phase contrast observation.

Hardware required for phase contrast observation:❶ CFI DL phase contrast objectives, ❷ GIF filter, ❸ Centering telescopeAnd either:❹ Phase contrast sliders (set of 2) or ❺ Phase Condenser with Condenser height adjustment tool

 

Darkfield observation

By inserting a slider for darkfield microscopy into the condenser slot and using oblique illumination, light scattered by specimens can be visualized. This method is effective for observation of unstained specimens such as live bacteria and examination of colloidal particles.

The CFI E Plan Achromat 4X objective is not suitable for darkfield observation.

Slider for darkfield microscopy

 

Simple polarizing observation

By attaching a polarizer to the field lens and an analyzer to the eyepiece tube mount, simple polarizing observation can be performed. The polarization state can be adjusted by turning the polarizer.

Polarizer and analyzer for simple polarizing

 

Diascopic fluorescence observation

Nikon has developed a unique diascopic fluorescence illumination method that enables easy fluorescence observation without attaching dedicated episcopic illuminator and fluorescence observation equipment. By simply inserting an EX filter slider into the condenser slot and a BA filter slider into the nosepiece slot, fluorescence observation of specimens expressing GFP or stained with fluorescent dyes such as FITC and Alexa 488 can be performed.

Diascopic fluorescence set

 

Online Guide accessible with a Smartphone

You can access a web-based operation manual for the ECLIPSE Si on your smartphone by simply scanning the QR code* sticker attached to the microscope. The Online Guide provides visual instructions including movies that enable you to quickly check how to setup and use the microscope. To access the Online Guide directly, click here.

* QR code is a registered trademark of DENSO WAVE INCORPORATED.


 

Emphasis on easy storage

The ECLIPSE Si also focuses on easy storage after observation. It features a lightweight, easy-to-carry design, and the power cord can also be conveniently housed.

 

Easy to Carry

The body of the ECLIPSE Si is 14% lighter than that of the previous model*. Grips on both sides of the microscope base and rear arms make it easy and stable to carry. In addition, the eyepieces can be securely fixed with screws to prevent them from falling during transportation.

* An LED model

Easy storage

The tube can be rotated backwards to reduce the space required for storage by loosening the tube locking screw. The tube is designed so that it does not fall even if the screw is loosened. The direction of rotation is clearly illustrated on the body.

Moreover, the AC adaptor can be stored at the back of the microscope, and the power cord can also be neatly wound up when storing.


 

Optional accessories

Digital Sight 1000 microscope camera

Equipped with a 2-megapixel CMOS image sensor, the Digital Sight 1000 can acquire color images and movies of up to 1920 x 1080 pixels. Just connect a monitor* and a mouse, and you can easily capture images without using a PC.

* Via a HDMI cable.

Simple measurements including distances between two points and areas are possible.

 

DS-Fi3 microscope camera

Equipped with a 5.9-megapixel CMOS image sensor, the DS-Fi3 can acquire high-resolution color images of up to 2880 x 2048 pixels*. Its excellent color reproducibility enables the acquisition of images with colors faithful to those of the images observed under the microscope. Its high sensitivity also makes the DS-Fi3 ideal for acquiring fluorescence images.

* NIS-Elements L imaging software is required for controlling the camera.


 

NIS-Elements L imaging software

By connecting the Digital Sight 1000 or DS-Fi3 to a tablet PC with NIS-Elements L installed, images of specimens under observation can be shared with other PCs via a network. The software also contains a variety of measurement and annotation functions.


 

Teaching Head

Enables simultaneous observation by two people using the same microscope. Available in two types: face-to-face type and side-by-side. Areas of interest can be indicated with the built-in LED pointer.

Face-to-face type Side-by-side type

 

Eye-level Riser

By mounting the eye-level riser under the eyepiece tube, the eyepoint can be raised by 25 mm. The height of the eyepiece can be adjusted to fit the observer, which allows observation in a comfortable posture.

Up to two pieces (50 mm) can be mounted.

 

Digital Sight 1000, DS-Fi3 microscope camera, and NIS-Elements L Imaging software are not for medical purposes.

Cooperation between pathological specimens and imaging guidance Dr. Yasushi Nakamura, Pathologist, Osaka Cytopathological Laboratory

Main Body ECLIPSE Si
Optical system CFI60 Infinity optical system
Illumination High luminescent white LED illuminator (Eco-illumination)

  • Built-in fly-eye lens
  • Up to two 45 mm diameter filters can be installed*1
  • Light Intensity Management (LIM) feature included
Focusing Coaxial coarse/fine focusing (located on both sides), cross roller guide
Focusing stroke: Up 2 mm/Down 13 mm, coarse: 37.7 mm per rotation, fine: 0.2 mm per rotation, minimum reading: 2 μm
With coarse focus knob torque adjustment ring and stage vertical movement stopper
ECLIPSE Si
Eyepieces (F.O.V., mm) With diopter adjustment

  • E2-CFI 10X (20)*2, E2-CFI 15X (12)*2
  • CFI 10X (22)*3
Tubes Inclination angle 45°, pupillary distance: 50-75 mm, eyepoint height: adjustable to 2 positions

  • EC-T-TB2 Binocular Tube 2
  • EC-T-TF2 Trinocular Tube F2
    (Eyepiece: Port: 50:50, built-in 0.55X relay lens in camera port, with C-mount)

Inclination angle 25°, pupillary distance: 50-75 mm

  • C-TB Binocular Tube
  • C-TF Trinocular Tube F (Eyepiece: Port = 100:0, 0:100)
  • C-TT Trinocular Tube T (Eyepiece: Port = 100:0, 20:80, 0:100) Inclination angle 10°-30°, extension: up to 40 mm
  • C-TE2 Ergonomic Binocular Tube (Eyepiece: Port = 100:0, 50:50 via optional C-TEP3 DSC Port C-0.55X)
Nosepiece Reversed-type quintuple nosepiece (within main body)
Stage Rectangular mechanical stage (within main body), with specimen holder 2L and vernier calibrations, cross travel: 76 (X) x 52 (Y) mm
Objectives (NA / W.D.)
  • CFI E Plan Achromat 4X (0.1/30mm)*4
  • CFI E Plan Achromat 10X (0.25/7mm)
  • CFI E Plan Achromat 40X (0.65/0.65mm)
  • CFI E Plan Achromat 60X (0.8/0.3mm)*4
  • CFI E Plan Achromat 100X Oil (1.25/0.23mm)*4

Objectives for phase contrast observation:

  • CFI Achromat DL 10X (0.25/7.0mm)
  • CFI Achromat LWD DL 20X (0.40/3.90mm)
  • CFI Achromat DL 40X (0.65/0.65mm)
  • CFI Achromat DL 100X Oil (1.25/0.23mm)

Other CFI60 objectives can also be used.

Condenser Abbe Condenser, NA 1.25, vertically movable and centerable
Observation methods*5 Brightfield, phase contrast, diascopic fluorescence, dark-field, simple polarizing
Fungus-proof treatment Antifungal paint is applied around optical system
Optional accessories
  • E2-SPH1 10X-40X PH slider/E2-SPH2 100X PH slider (used with phase contrast objectives)
  • Phase Condenser (used with phase contrast objectives)*6
  • E2-F-FL Dia-FL set GFP-B
  • E2-SDF dark-field slider
  • E2-DP simple polarizer, E2-PSA simple analyzer
  • EC-ER eye-level riser
  • E2-F-BF blue light blocking filter
  • Object marker*6*7
  • Eyepiece pointer
  • Teaching head
Power supply Uses the included AC adapter (input: 100-240 VAC, 0.48A Max., 50-60 Hz, output: 5.0 VDC, 3.0A Max.)
Power consumption (max.) Nominal value: 5 W
Weight (approx.) Approx. 6.0kg (when equipped with binocular tube), approx. 6.4kg (when equipped with trinocular tube)

*1 If the thickness is 2.5 mm or less. When a simple polarizer is attached, only one filter can be installed
*2 Used in combination with EC-T-TB2 Binocular Tube 2 or EC-T-TF2 Trinocular Tube F2
*3 Used in combination with C-TB Binocular Tube, C-TF/C-TT Trinocular Tubes or C-TE2 Ergonomic Binocular Tube
*4 Cannot be used for dark-field observation
*5 Observations other than brightfield require optional accessories
*6 Not for medical purposes
*7 A C-OA 15mm adapter is required

Digital Sight 1000, DS-Fi3 microscope camera, and NIS-Elements L Imaging software are not for medical purposes.
Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer.

 

Dimensional diagram

Request a Quote Brochures

View Other Similar Products

Upright Microscope Eclipse Ni Series
Upright Microscope Eclipse Ni-U
Clinical Upright Microscope Eclipse Ci Series
Upright Microscope Eclipse FN 1
Upcoming Events
8th July 2025 - 11th July 2025
Date: 8th July 2025 to 11th July 2025   Venue:…
3rd July 2025 - 5th July 2025
Date: 3rd July 2025 to 5th July 2025 Venue: Nanyang…
Products
  • Microscopy
  • Advanced Microscopy
  • Scientific Camera
  • Spectroscopy
  • Laser & Light Sources
  • Digital / High Content / Portable Microscope
  • Microscopy Accessories
  • Others
  • Bio-Medical
Services
  • Preventive Maintenance Microscope
  • Repairs
  • Relocation/Recommission
  • Training
  • Calibration
Engineering
  • Customization
  • Prototyping
Get in Touch

EINST Technology Pte Ltd.

1092, Lower Delta Road
#04-01-Singapore 169203

Tel: (65) 6276 6928

Fax: (65) 6276 1558

Email: admin@einstinc.com

connect with us

Copyright © 2025 Einstinc. All Rights Reserved. Sitemap

  • Home
  • About Us
    ▼
    • Latest News
    • Upcoming Events
    • Past Year Calendar Photos
    • Career
  • Products
  • Engineering
    ▼
    • Prototyping
    • Customization
  • Services
    ▼
    • Preventive Maintenance
    • Repairs
    • Relocation/Recommission
    • Training
    • Calibration
  • Technology
    ▼
    • Application
    • Publications
    • Microscopy Basics
  • Supplier
  • Contact Us