Calibration light sources

For wavelength calibration, Avantes offers a variety of sources including Argon, Mercury-Argon, Neon, Zinc, and Cadmium. All Avantes spectrometers are factory wavelength calibrated and do not require recalibration as they have fixed slits and optics. For those customers who wish to do their own calibrations, the AvaLight-CAL light sources can be used for recalibration purposes. For auto-calibration, AvaSoft-Fill provides a calibration procedure to make this easy.

 

The AvaLight-CAL-xxx is a spectral calibration lamp, available in Mercury-Argon (253.6-922.5 nm), Neon (337-1084.5 nm), Argon (696.5-1704 nm) Zinc (202.5-636.2 nm), and Cadmium (214.4-643.8 nm) versions. The major lines including their relative intensity and structures are shown below.

The standard SMA-905 connector supplies an easy connection between the lamp and optical fibres, making the AvaLight-CAL-xxx a low-cost wavelength calibration system for any fibre-optic spectrometer. AvaSoft-Full spectroscopy software includes an automatic recalibration procedure.

The AvaLight-CAL-Mini, AvaLight-CAL-AR-Mini, AvaLight-CAL-Neon-Mini all come in the Mini-housing and are equipped with a connector at the rear enabling to switch the unit on/off remotely with a TTL signal.

The AvaLight-CAL can also be delivered in rack-mountable version, to be integrated into Avantes 19” Rack-mount or the 9.5” desktop housing. The PS-12V/2.08A power supply should be ordered separately.

 

 

Benefits

  • Compact calibration light source
  • Low cost
  • Available in a variety of wavelength ranges (from UV to NIR)

 

 

Technical Data

HgAr Neon Ar Zinc Cadmium
Output 253.6-922.5 nm 337-966 nm 950-1704 nm 202.5-636.2 nm 214.4-634.8 nm
Optical power in 600 µm fiber 1.6 µW 1.6 µW 1.6 µW 1.6 µW 1.6 µW
Connector SMA-905 SMA-905 SMA-905 SMA-905 SMA-905
Internal voltage 1000 VAC at 35 kHz, 11 mA 1000 VAC at 35 kHz, 11 mA 1000 VAC at 35 kHz, 11 mA 1500 VAC at 27 kHz, 47.5 mA 1500 VAC at 27 kHz, 47.5 mA
Warm-up time 1 minute for vapor stabilization 1 minute for vapor stabilization 1 minute for vapor stabilization <10 minutes <10 minutes
Lamp lifetime 5000 hours 5000 hours 5000 hours 1000 hours 1000 hours
Power requirement 12 VDC supply, 260 mA 12 VDC supply, 260 mA 12 VDC supply, 260 mA 85-240 VAC, 1.0 A 85-240 VAC, 1.0 A
Dimensions, weight 150 x 78 x 37 mm, 510 g 150 x 78 x 37 mm, 510 g 150 x 78 x 37 mm, 510 g Lamp unit: 175 x 110 x 44 mm, 480 g, power supply unit: 102 x 167 x 58 mm, 450 g Lamp unit: 175 x 110 x 44 mm, 480 g, power supply unit: 102 x 167 x 58 mm, 450 g

 

 

Ordering Information

AvaLight-CAL-Mini Mercury Argon Calibration source needs extra PS-12V/2.08A power supply, SMA
AvaLight-CAL-NEON-Mini Neon Calibration source needs extra PS-12V/2.08A power supply, SMA
AvaLight-CAL-AR-Mini Argon Calibration source needs extra PS-12V/2.08Apower supply, SMA
AvaLight-CAL-RM-Mini Rack-mounted version of AvaLight-CAL
AvaLight-CAL-B-Mini Replacement bulb, Mercury-Argon
AvaLight-CAL-NEON-B-Mini Replacement bulb, Neon
AvaLight-CAL-AR-B-Mini Replacement bulb, Argon
AvaLight-CAL-ZINC Zinc Calibration Light source, including power supply
AvaLight-CAL-CAD Cadmium Calibration Light source, including power supply
AvaLight-CAL-ZINC-B Zinc replacement bulb
AvaLight-CAL-CAD-B Cadmium replacement bulb
PS-12V/2.08A Power supply 100-240VAC/12VDC, 2.08A for AvaLight-CAL-Mini series

 

Calibrating your spectrometer has never been easier: the AvaLight-HAL-CAL-Mini and Avalight-DH-CAL are NIST(National Institute of Standards and Technology)-traceable, calibrated light sources used to measure absolute spectral intensity.

The AvaLight-HAL-CAL-Mini is a compact, affordable light source. It is calibrated for the visible range (350-1095 nm). Optionally, an extended calibration for the near-infrared spectral range (1100 – 2500 nm) can be ordered. It has a built-in diffuser, a cosine corrector with SMA adapter and comes with a calibration file in ASCII format. Calibration can be done using the AvaSoft software.

The AvaLight-HAL-CAL-ISPxx-Mini is a special version of the Avalight-HAL-CAL-Mini, which enables coupling any of Avantes’ AvaSphere-xx-IRRAD integrating spheres to the lightsource (xx = 30, 50 or 80) for calibration. This source is supplied with a special bottom plate to stabilize the AvaSphere. The Avalight-HAL-CAL-Mini and Avalight-HAL-CAL-ISPxx-Mini include a power supply.

 

 

Benefits

  • Field calibration
  • Visible and optional NIR range
  • Built-in diffuser
  • Compact and versatile

 

AvaLight-DH-CAL

For calibrations in the ultraviolet and visible range (200 – 1099 nm), the AvaLight-DH-CAL is the best solution. This source can be used with all AvaSpec spectrometers to calibrate for absolute spectral intensity. It is supplied with a built-in diffuser, a cosine corrector (CC-VIS/NIR) with SMA adapter, and a USB containing the calibration files in ASCII format.

AvaLight DH CAL Centred

Two calibration files are included: one for irradiance calibration over the full range (200 – 1099 nm) and one over the visible and near-infrared range (350-1099 nm). For the first file, both the deuterium and the halogen bulb should be used during calibration. The second file is to be used with only the halogen light. The halogen-only spectrum provides a smoother black-body calibration spectrum for the longer wavelengths.

For a more balanced spectrum across the 200 to 1100 nm range, Avantes offers the AvaLight-DH-BAL-CAL. For ultraviolet range calibration only (200-400 nm), the AvaLight-D-CAL is the right choice.

The calibration files can be imported into the AvaSoft-IRRAD application software, for intensity calibration which turns your spectrometer into a spectroradiometer.

The AvaLight-DH-CAL-ISPxx is a special version of these calibrated light sources, meant to facilitate coupling of the AvaSphere-xx-IRRAD integrating spheres to the light source. (xx is 30, 50 or 80). The AvaLight-DH-CAL, AvaLight-DH-BAL-CAL and AvaLight-D-BAL-CAL all include a power supply.

image 8
Spectral output AvaLight-HAL-CAL and AvaLight-DH-CAL

Technical Data

AvaLight-HAL-CAL-Mini AvaLight-DH-(BAL-)CAL
Calibration use Irradiance µW cm-2 nm-1 Irradiance µW cm-2 nm-1
Calibration surface CC-VIS/NIR or AvaSphere CC-VIS/NIR or AvaSphere
Wavelength range 350-1095nm/1100-2500 nm* 200-1099nm
Calibration repeatability ± 0.5 % ±1.0 %
Calibration relative uncertainty to NIST standard ±5.0% (350-1100 nm); 3.5%(1100-1950); 5.0% (1950-2500nm) ±10% (200-240 nm);9% (240-350 nm);10% (350-400 nm);9.5%(400-1100 nm)
Calibration valid for 60 hrs 60 hrs
Warm-up time Ca. 15 min Ca. 30 min
Bulb output 170 µW cm-2 nm-1 (@800 nm) 80 µW cm-2 nm-1 (@215 nm); 5 µW cm-2 nm-1 (@800 nm)
Power requirement 12 V/2.08 A 100-240 VAC
Dimensions 150 x 78 x 37 mm 315 x 165 x 140 nm

*Optional extended range NIR calibration

 

 

Ordering Information

AvaLight-HAL-CAL-Mini NIST traceable Halogen Lamp with CC- VIS/NIR diffuser, incl. PS-12V/2.08A
AvaLight-HAL-CAL-ISP30-Mini NIST traceable Halogen Lamp for use with AvaSphere-30-IRRAD, incl. PS-12V/2.08A and special sphere holder bottom plate
AvaLight-HAL-CAL-ISP50-Mini As AvaLight-HAL-CAL-ISP30 for use with AvaSphere-50-IRRAD
AvaLight-HAL-CAL-ISP80-Mini As AvaLight-HAL-CAL-ISP30 for use with AvaSphere-80-IRRAD
HL-Recal AvaLight-HAL-CAL recalibration service 350-1095 nm
HL-Recal-NIR AvaLight-HAL-CAL extended or recalibration service 1100-2500 nm
AvaLight-D-CAL NIST traceable UV Deuterium Lamp with CC-VIS/NIR diffuser, -SR fibers recommended
AvaLight-DH-CAL NIST traceable UV/VIS Deuterium/Halogen Lamp with CC-VIS/NIR diffuser, -SR fiber recommended
AvaLight-DH-BAL-CAL As AvaLight-DH-CAL, but balanced UV/VIS Deuterium/Halogen
AvaLight-DH-CAL-ISP30 NIST traceable UV/VIS Deuterium/Halogen Lamp for use with AvaSphere-30-IRRAD, incl. special sphere holder bottom plate, -SR fibers recommended
AvaLight-DH-CAL-ISP50 As AvaLight-DH-CAL-ISP30 for use with AvaSphere-50-IRRAD
AvaLight-DH-CAL-ISP80 As AvaLight-DH-CAL-ISP30 for use with AvaSphere-80-IRRAD
DH-recal AvaLight-DH-CAL recalibration service 200-1099 nm
AvaSoft-IRRAD Irradiance add-on software, to be ordered with AvaSoft-Full