Our pulsed Xenon light source is used in applications where a long lifetime and high output power is needed, such as in fluorescence measurements. This is an affordable UV source, but the spectral output is not as smooth and continuous as the AvaLight Halogen and Deuterium light sources.
The AvaLight-XE is a pulsed xenon light source, perfect for ultraviolet applications like fluorescence. When connected to your AvaSpec spectrometer through the IC-DB26-2 cable (sold separately), the flashes are synchronized with the data collected by the spectrometer. The number of flashes per scan can be selected in AvaSoft.
With a special DUV bulb, the AvaLight-XE can be used for deep-ultraviolet applications (below 200 nm). A special direct-attach cuvette holder is available for your fluorescence applications. For transmission measurements, the light source can be used in conjunction with the CUV-ATT-DA, which has an iris attenuator to limit the light output and avoid saturation.
Technical Data
Spectral output | 200-1000 nm |
Total optical power output | 39 µJ per pulse (average 66 mW) |
Optical power in 200 µm fiber | 0.66 µJ per pulse (average 20 µW) |
Optical power in 600 µm fiber | 3.2 µJ per pulse (average 320 µW) |
Optical power in 1000 µm fiber | 7.4 µJ per pulse (average 744 µW) |
Synchronization input | 15 pin sub-D connector, TTL level |
Pulse duration | 5 µs (at 1/3 height) |
Pulse delay | 6 µs |
Pulse rate (max.) | 100 Hz |
Bulb life | Min. 10 9 pulses |
Connector | SMA-905 connector |
Power requirement | 12 VDC/550 mA |
Dimensions, weight | 175 x 110 x 44 mm, 540 g |
Ordering Information
AvaLight-XE | 2 W xenon light source (200-1000 nm), needs interface cable and power supply |
AvaLight-XE-DUV | Deep-UV (160-1000 nm) version of the AvaLight-XE, needs interface cable and power supply |
AvaLight-XE-B | Spare bulb for the AvaLight-XE |
AvaLight-XE-B-DUV | Spare bulb for the AvaLight-XE-DUV |
IC-DB26-2 | Interface cable from AvaSpec-USB2/EVO platform to AvaLight-XE |
CUV-DA | Direct-attach cuvette holder for AvaLight-DHc/XE/LED |
ATT-DA | Direct-attach attenuator for AvaLight-DHc/XE/LED |
CUV-ATT-DA | Direct-attach cuvette holder and attenuator for AvaLight-DHc/XE/LED |
PS-12V/2.08A | Power supply 100-240 VAC/12 VDC, minimal 1.0 A for AvaLight-XE |
The AvaLight-XE-HP is a pulsed xenon light source, perfect for ultraviolet applications, such as fluorescence. This high-power light source comes in a compact housing, making it very well-suited for integration into a customers existing systems. Compared to the AvaLight-XE (2W), the XE-HP provides significantly more power.
When connected to your AvaSpec spectrometer through the Y cable, the flashes are synchronized with the data collected by the spectrometer. The number of flashes per scan can be selected in AvaSoft.
Technical Data
Spectral output | 200 nm to 1000 nm |
Total optical power output | Max. 6 W/39 mJ per flash |
Synchronization input | 9 pin sub-D connector, TTL level |
Pulse rate (max.) | 150 Hz |
Long life | > 1,0 x 10 9 flashes |
Connector | SMA-950 connector |
Power requirement | 11-28 VDC/2.08 A |
Dimensions, weight | 98 x 44 x 35 mm, 192 g |
Ordering Information
AvaLight-XE-HP | 6 W xenon light source (200-1000 nm) with Y-cable for powered trigger connection to AvaSpec-EVO. Needs PS-12V/2.08A power supply |
PS-12V/2.08A | Power supply 100-240 VAC/12 VDC, 2.08 A for AvaLight-XE-HP |
CC-VIS/NIR-SMA | Cosine Corrector with diffusing material for UV/VIS/NIR. Onde side SMA-female; Other SMA-male |
IC-XE-HP-WTB-2 | Interface cable incl. pwr, DB9 to WTB and pwr, 2m for XE-HP to AvaSpec-Mini MK2 IO connector and power supply |